Operation mode:12/24VDC
Application area:8-stage chargers ane suitable for most battery types including WET,MF, Calcium, AGM, and GEL batteries. They may also help restore drained and sulphated batteries.
This is a fully automatic battery charger with 8 charge stages.
Automatic charging protects your battery from being overcharged. So you can leave the charger connected to the battery indefinitely.
8-stage charging is a very comprehensive and accurate charging process that gives your battery longer life and better performance compared to using traditional chargers.
8-stage chargers ane suitable for most battery types including WET,MF, Calcium, AGM, and GEL batteries. They may also help restore drained and sulphated batteries.
Desulphation
The Desulphation stage may break down sulphation that occurs in batteries that have been life flat for extended periods of time,returning them back to full charge, sulpnation occurs when lead-sulphate hardens and clogs up the battery cells.
Soft Start
A preliminary charge processes that gently introducesThis protects the battery and increases battery life.
Bulk (Constant Current)
Charging with maximum current until approximately 80% battery capacity.
Absorption (Constant Voltage)
Charging with declining current to maximize up to 100% battery capacity.
Analyse
An automatic battery test is conducted immediately after the absorption stage. The test monitor the voltage for 90 seconds to determine if the charge was successful.
Recondition
Choose the Recond program to add the Recond step to the charging process. During the Recond step voltage increases create controlled.gasing in the battery. Gasing mixes thebattery add and gives back energy to the battery.
Float
The Float stage maintains the battery at 100% charge without overcharging or damaging the battery. This means the charger can be left connected to the battery indefinitely.
Pulse
Maintaining the battery at 95-100% capacity. The charger monitors the battery voltage and gives a pulse when necessary to keep the battery fully charged.
The battery charger has an 8-step fully automatic charging cycle. the cycle is repeated infinity. If the terminal voltage drops below a lower limit, the charger automatically goes back to the beginning of the charging curve.
8-stage chargers ane suitable for most battery types including WET,MF, Calcium, AGM, and GEL batteries. They may also help restore drained and sulphated batteries.
Type | 8-Stage automatic | |||||||
Input Voltage | 220-240V〜,50 | Tz/llOV〜60Hz | ||||||
Input Power | 154W | 215W | 307W | 332W | 415W | 554W | 296W | 547W |
Output Voltage | 12VDC | 12VDC | 12VDC | 12VDC | 12VDC | 12VDC | 24VDC | 24VDC |
Output Current | 5A | 7A | 10A | 12A | 15A | 20A | 5A | 10A |
Minimum Start Voltage | 2V | 2V | 2V | 2V | 2V | 2V | 4V | 4V |
Back Drain | 1mA | 1mA | 1mA | 1mA | 1mA | 1mA | 1mA | 1mA |
Current Fuse Rating | 250VACJ3J5A | 250VACJ3.15A | 250VAC,T3,15A | 250VAC,T3,15A | 250VACJ3,15A | 250VACJ5A | 250VACJ3J5A | 250VAC.T5A |
CHARGE CONTROL | ||||||||
Desulphation | Pulse charger up to 11V | Pulse charger up to 22V | ||||||
Soft Start | Half the rated set current up to 12.5V | Half the rated set current up to 25V | ||||||
Bulk | 5A up to 14.4V 14.1V(GEL) 14.4V(AGM) 14.7V(WET) 14.7V(CALCIUM) | 7Aupto 14.4V 14.1V(GEL) 14.4V(AGM) 14.7V(WET) 14.7V(CALCIUM) | lOAupto 14.4V 14.1V(GEL) 14.4V(AGM) 14.7V(WET) 14.7V(CALCIUM) | 12A up to 14.4V 14.1V(GEL) 14.4V(AGM) 14.7V(WET) 14.7V(CALCIUM) | 15A up to 14.4V 14.1V(GEL) 14.4V(AGM) 14.7V(WET) 14.7V(CALCIUM) | 20A up to 14.4V 14.1V(GEL) 14.4V(AGM) 14.7V(WET) 14.7V(CALCIUM) | 5A up to 14.4V 28.2V(GEL) 28.8V(AGM) 29.4V(WET) 29.4V(CALCIUM) | lOAupto 14.4V 28.2V(GEL) 28.8V(AGM) 29.4V(WET) 29.4V(CALCIUM) |
Absorption | Constant voltage until current drops to 0.75A | Constant voltage until current drops to 1.05A | Constant voltage until current drops to 1.5A | Constant voltage until current drops to 1.8A | Constant voltage until current drops to 2.25A | Constant voltage until current drops to 3.0A | Constant voltage until current drops to 0.75A | Constant voltage until current drops to 0.75A |
Analyse | Monitors voltage for 90 seconds | |||||||
Recondition | Constant voltage (0.75A) for30(ninor4hours limited to: 14.1V(GEL) 14.4V(AGM) 16.0V(WET) 16.0(CALCIUM) | Constant voltage (1.05A) for30minor4hours limited to: 14.1V(GEL) 14.4V(AGM) 16.0V(WET) 16.0(CALCIUM) | Constant voltage (1.5A) for 30minor4hours limited to: 14.1V(GEL) 14.4V(AGM) 16.0V(WET) 16.0(CALCIUM) | Constant voltage (1-8A) for30minor4hours limited to: 14.1V(GEL) 14.4V(AGM) 16.0V(WET) 16.0(CALCIUM) | Constant voltage (2.25A) for30minor4hours limited to: 14.1V(GEL) 14.4V(AGM) 16.0V(WET) 16.0(CALClUM) | Constant voltage (3.0A) for30minor4hours limited to: 14.1V(GEL) 14.4V(AGM) 16.0V(WET) 16.0(CALClUM) | Constant voltage (0.75A) for30minor4hours limited to: 28.2V(GEL) 28.8V(AGM) 32.0V(WET) 32.0(CALCIUM) | Constant voltage (1-5A) for 30minor4hours limited to: 28.2V(GEL) 28.8V(AGM) 32.0V(WET) 32.0(CALCIUM) |
Float | 13.7V also wit | pulse feature | 27.4V also wit | pulse feature | ||||
Pulse | 126V44.1V.5-2A(GEL) 12.6V-14.4V5-2A(AGM) 12.6VM.7VS2A(WET) 126V447V.S-2A (CALCIUM) | 12.6V-14.1V7-2A(GEU 12.6V-144V.7-2A(AGM) 12.6V-14.7V7-2A(WED 126V-14.7V7.2A (CALCIUM) | 12.6V441V10-2A(GEU 12.6V-144V10-2A{AGM) 12.6V14.7V10-2AJWET) 12.6V-14.7V10-2A (CALCIUM) | 12.W-W1V12-2A(GEL) 12.6V-14.4V12-2A(AGM) 126V147V12-2A(WED 126V-14.AG2-2A (CALCIUM) | 126V-14.1V15-2A(GEl) 126V-144V15-2A(/\GM) U6V 14.7V 15-2A(WEr) 12.6V-14.7V 15-2A (CALOUM) | 126V441V20-2A(GEU l26V-b14V20-2A(AGM! 12.6V 14 7V2O-2A(WED 126V44.7V20-2A (CALCIUM) | 252V-282V5-2A(GEU 252V-283v 5-2&AGM) 252Vg4V52HWEI) 252V-29.4V5-2A (CALCIUM) | 252V-282V.10-2A<GEL) 252V-288V.10-2A(AGM) 252V294V.10-2A(WED 252V-29.4V10-2A (CALCIUM) |
Efficiency | App.85% | |||||||
Thermal Protect | 65℃±5℃ | |||||||
Cooling Fan | Automatic temperature controlled | |||||||
Ambient Temperature | -20℃ to +50℃, output power is reduced automatically at high temperature | |||||||
Over Voltage Protection | the 12V charger will automatically protection if the voltage is higher than 17.5V | the 24V chargerwill automatically protection if the voltage is higherthan 35V | ||||||
BATTERY RANGE | ||||||||
Deep Cycle | 35-100Ah | 50-140Ah | 70-200Ah | 80-240Ah | 100-300Ah | 134-400Ah | 35-lOOAh | 70-200Ah |
Types of Batteries | Most types of lead acid batteries including Calcium. GEL and AGM | |||||||
Dimension(LxWxHmm) | 190x115x62 | 190x115x62 | 190x115x62 | 215x115x62 | 215x115x62 | 215x115x62 | 215x115x62 | 215x115x62 |
Weight(kg) | 1 | 1.03 | 1.1 | 1.1 | 1.2 | 1.2 | 1.1 | 1.2 |
Internal fuses should only be replaced by qualified elevtrical appliance repairer.
1.Polarity protection
2.Output short protection
3.Non battery link protection
4.Disconnect protection
5.Over voltage protection
6.Over temperature protection
7.Automatic temperature controlled cooling fan.