86-10-88861978/79/80/81/82
中文EN
Home > Product > Battery Charger > VCB Series

VCB Series

Operation mode:12/24VDC

Application area:8-stage chargers ane suitable for most battery types including WET,MF, Calcium, AGM, and GEL batteries. They may also help restore drained and sulphated batteries.

Submit online

Submit online
  • Name:
  • *phone:
  • Telephone:
  • Company:
  • *E-mail:
  • Remarks:
  • Product overview
  • Characteristic
  • Application
  • Technical
  • Protection function

This is a  fully automatic battery charger with 8 charge stages.

Automatic charging protects your battery from being overcharged. So you can leave the charger connected to the battery indefinitely.

8-stage charging is a very comprehensive and accurate charging process that gives your battery longer life and better performance compared to using traditional chargers.

8-stage chargers ane suitable for most battery types including WET,MF, Calcium,  AGM, and GEL batteries. They may also help restore drained and sulphated batteries.


Desulphation

The Desulphation stage may break down sulphation that occurs in batteries that have been life flat for extended periods of time,returning them back to full charge, sulpnation occurs when lead-sulphate hardens and clogs up the battery cells.

Soft Start

A preliminary charge processes that gently introducesThis protects the battery and increases battery life.

Bulk (Constant Current)

Charging with maximum current until approximately 80% battery capacity.

Absorption (Constant Voltage)

Charging with declining current to maximize up to 100% battery capacity.

Analyse

An automatic battery test is conducted immediately after the absorption stage. The test monitor the voltage for 90 seconds to determine if the charge was successful.

Recondition

Choose the Recond program to add the Recond step to the charging process. During the Recond step voltage increases create controlled.gasing in the battery. Gasing mixes thebattery add and gives back energy to the battery.

Float

The Float stage maintains the battery at 100% charge without overcharging or damaging the battery. This means the charger can be left connected to the battery indefinitely.

Pulse

Maintaining the battery at 95-100% capacity. The charger monitors the battery voltage and gives a pulse when necessary to keep the battery fully charged.


The battery charger has an 8-step fully automatic charging cycle. the cycle is repeated infinity. If the terminal voltage drops below a lower limit, the charger automatically goes back to the beginning of the charging curve.


8-stage chargers ane suitable for most battery types including WET,MF, Calcium,  AGM, and GEL batteries. They may also help restore drained and sulphated batteries.

Type8-Stage automatic
Input Voltage220-240V〜,50Tz/llOV〜60Hz
Input Power154W215W307W332W415W554W296W547W
Output Voltage12VDC12VDC12VDC12VDC12VDC12VDC24VDC24VDC
Output Current5A7A10A12A15A20A5A10A
Minimum Start Voltage2V2V2V2V2V2V4V4V
Back Drain1mA1mA1mA1mA1mA1mA1mA1mA
Current Fuse Rating250VACJ3J5A250VACJ3.15A250VAC,T3,15A250VAC,T3,15A250VACJ3,15A250VACJ5A250VACJ3J5A250VAC.T5A
CHARGE CONTROL
DesulphationPulse charger up to 11VPulse charger up to 22V
Soft StartHalf the rated set current up to 12.5VHalf the rated set current up to 25V
Bulk5A up to 14.4V 14.1V(GEL)   14.4V(AGM) 14.7V(WET) 14.7V(CALCIUM)7Aupto 14.4V 14.1V(GEL)   14.4V(AGM) 14.7V(WET) 14.7V(CALCIUM)lOAupto 14.4V 14.1V(GEL)   14.4V(AGM) 14.7V(WET) 14.7V(CALCIUM)12A up to 14.4V 14.1V(GEL)   14.4V(AGM) 14.7V(WET) 14.7V(CALCIUM)15A up to 14.4V 14.1V(GEL)   14.4V(AGM) 14.7V(WET) 14.7V(CALCIUM)20A up to 14.4V 14.1V(GEL)   14.4V(AGM) 14.7V(WET) 14.7V(CALCIUM)5A up to 14.4V 28.2V(GEL)   28.8V(AGM) 29.4V(WET) 29.4V(CALCIUM)lOAupto 14.4V 28.2V(GEL)   28.8V(AGM) 29.4V(WET) 29.4V(CALCIUM)
AbsorptionConstant voltage until current   drops to 0.75AConstant voltage until current   drops to 1.05AConstant voltage until current   drops to 1.5AConstant voltage until current   drops to 1.8AConstant voltage until current   drops to 2.25AConstant voltage until current   drops to 3.0AConstant voltage until current   drops to 0.75AConstant voltage until current   drops to 0.75A
Analyse
Monitors voltage for 90 seconds
ReconditionConstant voltage (0.75A)   for30(ninor4hours limited to: 14.1V(GEL) 14.4V(AGM) 16.0V(WET) 16.0(CALCIUM)Constant voltage (1.05A)   for30minor4hours limited to: 14.1V(GEL) 14.4V(AGM) 16.0V(WET) 16.0(CALCIUM)Constant voltage (1.5A) for   30minor4hours limited to: 14.1V(GEL) 14.4V(AGM) 16.0V(WET) 16.0(CALCIUM)Constant voltage (1-8A)   for30minor4hours limited to: 14.1V(GEL) 14.4V(AGM) 16.0V(WET) 16.0(CALCIUM)Constant voltage (2.25A)   for30minor4hours limited to: 14.1V(GEL) 14.4V(AGM) 16.0V(WET) 16.0(CALClUM)Constant voltage (3.0A)   for30minor4hours limited to: 14.1V(GEL) 14.4V(AGM) 16.0V(WET) 16.0(CALClUM)Constant voltage (0.75A)   for30minor4hours limited to: 28.2V(GEL) 28.8V(AGM) 32.0V(WET) 32.0(CALCIUM)Constant voltage (1-5A) for   30minor4hours limited to: 28.2V(GEL) 28.8V(AGM) 32.0V(WET) 32.0(CALCIUM)
Float13.7V also witpulse feature27.4V also witpulse feature
Pulse126V44.1V.5-2A(GEL)   12.6V-14.4V5-2A(AGM) 12.6VM.7VS2A(WET) 126V447V.S-2A (CALCIUM)12.6V-14.1V7-2A(GEU   12.6V-144V.7-2A(AGM) 12.6V-14.7V7-2A(WED 126V-14.7V7.2A (CALCIUM)12.6V441V10-2A(GEU   12.6V-144V10-2A{AGM) 12.6V14.7V10-2AJWET) 12.6V-14.7V10-2A (CALCIUM)12.W-W1V12-2A(GEL)   12.6V-14.4V12-2A(AGM) 126V147V12-2A(WED 126V-14.AG2-2A (CALCIUM)126V-14.1V15-2A(GEl)   126V-144V15-2A(/\GM) U6V 14.7V 15-2A(WEr) 12.6V-14.7V 15-2A (CALOUM)126V441V20-2A(GEU   l26V-b14V20-2A(AGM! 12.6V 14 7V2O-2A(WED 126V44.7V20-2A (CALCIUM)252V-282V5-2A(GEU 252V-283v   5-2&AGM) 252Vg4V52HWEI) 252V-29.4V5-2A (CALCIUM)252V-282V.10-2A<GEL)   252V-288V.10-2A(AGM) 252V294V.10-2A(WED 252V-29.4V10-2A (CALCIUM)
EfficiencyApp.85%
Thermal Protect65℃±5℃
Cooling FanAutomatic temperature controlled
Ambient Temperature-20℃ to +50℃, output power is reduced automatically   at high temperature
Over Voltage Protectionthe 12V charger will automatically protection if the   voltage is higher than 17.5Vthe 24V chargerwill   automatically protection if the voltage is higherthan 35V
BATTERY RANGE
Deep Cycle35-100Ah50-140Ah70-200Ah80-240Ah100-300Ah134-400Ah35-lOOAh70-200Ah
Types of BatteriesMost types of lead acid batteries including Calcium.   GEL and AGM
Dimension(LxWxHmm)190x115x62190x115x62190x115x62215x115x62215x115x62215x115x62215x115x62215x115x62
Weight(kg)11.031.11.11.21.21.11.2

Internal fuses should only be replaced by qualified elevtrical appliance repairer.

1.Polarity protection

2.Output short protection

3.Non battery link protection

4.Disconnect protection

5.Over voltage protection

6.Over temperature protection

7.Automatic temperature controlled cooling fan.


Tel:86-10-88861978/79/80/81/82 Email: renjingzhu@263.net Add:Room 8B, 2# Block A, Golden Resource Business Center, HaiDian Beijing China