86-10-88861978/79/80/81/82
中文EN
Home > Product > Power Inverter > Vehicle USE

CRV1600-5000W(Efficienttype)

Operation mode:Input:12/24VDC ; Output:220V Single-Phase

Application area:RV, Motor home, Ambulance, Bloodmobile, Rescue ambulance, Physical examination vehicle, Dental vehicle, Food&Drug testing vehicle, Military &Police vehicle, Media outside broadcasting vehicle,

Submit online

Submit online
  • Name:
  • *phone:
  • Telephone:
  • Company:
  • *E-mail:
  • Remarks:
  • Product overview
  • Characteristic
  • Application
  • Technical

Different from normal inverter, CRV Series vehicle-mounted inverter is designed for vehicle. In the light of the functional features of vehicle, the inverter's structure was designed and could withstand vibration for long time when vehicle is running(the inverter passed the vibration test in the lab in X. Y. Z three directions.)  CRV inverter could run in -40°C-+50°C (90% humidity) with full load. The battery isolators could be installed inside the inverter.

The output voltage of inverter could not decreased with the capacity of battery lower or the capacity of load increase cause the inverter's power is sufficient. The inverter and life battery will not damaged by load, environment and rough usage cause various protection functions. The inside power components have low calorific value and the cooling fans are no need to long time run, so users will not be disturbed by the noise from fan.


1.Low frequency Pure sine wave for output.

2.The output voltage of inverter could not decreased with the capacity of battery lower or the capacity of load increase cause the inverter's power is sufficient

3.Low loss.

4.The inverter could be with instantaneous 3 times rated load at least. The air-condition, fridge and air pump could be used.

5.Digital and LED display is direct, simple and visual. User will not be disturbed by light or sound if press the mute and extinction button.

6.The type of battery could be chose;

7.The charging current could be chose;

8.The inverter could be started even no battery with normal AC.

9.Various protection functions: over charging, over discharging, over load, over temperature inside inverter, over temperature for life battery and output short and so on.

10.Various type of generator could be connected with input of inverter.

11.According to reality, the battery isolators could parallel or separate the vehicle battery and life battery.

12.Residential water and sweage level test switch for water pump function, (optional)


RV, Motor home, Ambulance, Bloodmobile, Rescue ambulance, Physical examination vehicle, Dental vehicle, Food&Drug testing vehicle, Military &Police vehicle, Media outside broadcasting vehicle, Helicopter, Yacht,etc.

Technical Parameters(Efficienttype)
ModelCRV1600CRV2000CRV2500CRV3000CRV5000
Rated Power(25℃)1600W/2000VA2000W/2500VA2500W/3125VA3000W/3750VA5000W/6250VA
Rated Power(40℃)1600W/2000VA2000W/2500VA2500W/3125VA3000W/3750VA5000W/6250VA
Peak Power4800W6000W7500W9000W15000W
Various   combinations
System voltage(DC)12V24V12V24V12V24V12V24V48V24V
1 ON.2ONOA0A0A0A0A0A0A0A0A0A
1 OFF.2OFF60A40A90A50A90A50A90A50A30A100A
1 ON,2 OFF(factory default)30A20A60A30A60A30A60A30A20A60A
1 OFF,2ON10A10A30A10A30A10A30A10A10A30A
Inverter Mode
Rated Voltage12VDC/24VDC                       112VDC/24VDC/48VDC24VDC
Output PowerNominal Value
Output Voltage220V/110V(110VNeed to be customized)
Output Frequency50Hz /60Hz (60Hz Need to be customized)
Output WaveformPure sine wave
Efficiency>85%
Peak Factor3:1
Overload Capacity100%-120%>1 min auto shut;120%-150%>30s auto   shutjabove 150% 10s auto shut;
Overload ProtectionBattery undervottage   protection, battery undervoltage protection, battery undervoltage shutdown   protection, output short circuit protection, inverter overtemperature   protection, backup battery over temperature protection
Type of loadResistive load, inductive load, capacitive load and   half wave load
AC Mode
Input Voltage Range160VAC-270VAC±5V(Beyond the range into the inverter   mode)
Input Frequency Range38-65Hz(Beyond the range into the inverter mode)
Charging Voltage14.4V ±0.2V(12V Systemj/28.8V ±0.2V(24V   System)/57.6V ±0.2V(48V System)
Charging Current(12V)0A,10A.30A.60A(factorydefault30A)0A.30A60A,90A(factorydefault60A)
Charging Current(24V)0A.10A.20A.40A   (factorydefault 20A)0A.10A,30A,50A(factorydefault 30A)OA.30A.60A.100A   (factorydefault60A)
Charging Current(48V)0A*10A,20A,30A(factorydefault20A)
Overload ProtectionThe over current protector is disconnected after   overload
Other
The inverter could be started in AC without battery. Generator:   All kinds of generator could be used(The power of generator is 1.5 times of   inverter's.)
Switching TimeAC to DC 5 10ms; DC to ACS 10ms
Protection ClassIP20
Cooling MethodForced air cooling
Water level monitoringOpbonal
TemperatureOperating temperature: -40℃ ~ 50℃ ; Storage   temperature:-40℃ -60℃
Working Humidity0%~95%
Noise level<40dB(1mj
No-load loss9W11W13W24.4W
Energy Saving Mode5W5W7W12W
Display Informationworking status.the votage and frequency of input and output.the capacity   of battery.the capacity of load,fault alarm
Product Size(mm)418(458)x256x165mm480(520)x256x190mn584(624)x306x190mm
Package Size(cm)68.0x33.0x28.0cm68.0x40.0x28.0cm68.0x40.0x28.0cm
Net weight (kg)24.0kg26.0kg28.0kg30.0kg43.0kg
Gross weight (kg)26.0kg28.0kg30.0kg32.0kg48.0kg
Backup Timebackup time(H)=battery capacity(Ah)÷discharge   current(A)
Battery modeExternal battery
Battery typeLead-acid maintenanc+A17:K49including deep cycle   battery j/GEL battery / Lithium polymer battery

Note:“Output power” decreases as altitude increases,for example, 1500m the output power=rating power*0.94, 3500m the output power=rating power*0.82。

        The date in the table above defaults to lead-acid maintenance-free batteries.

        Specially available AC115V, AC120V, AC127V.


Tel:86-10-88861978/79/80/81/82 Email: renjingzhu@263.net Add:Room 8B, 2# Block A, Golden Resource Business Center, HaiDian Beijing China
Copyright© 2002-2021   Beijing Prostar International Electric Co., Ltd.   www.prostarele.com