Operation mode:Input:12/24VDC ; Output:220V Single-Phase
Application area:RV, Motor home, Ambulance, Bloodmobile, Rescue ambulance, Physical examination vehicle, Dental vehicle, Food&Drug testing vehicle, Military &Police vehicle, Media outside broadcasting vehicle,
Different from normal inverter, CRV Series vehicle-mounted inverter is designed for vehicle. In the light of the functional features of vehicle, the inverter's structure was designed and could withstand vibration for long time when vehicle is running(the inverter passed the vibration test in the lab in X. Y. Z three directions.) CRV inverter could run in -40°C-+50°C (90% humidity) with full load. The battery isolators could be installed inside the inverter.
The output voltage of inverter could not decreased with the capacity of battery lower or the capacity of load increase cause the inverter's power is sufficient. The inverter and life battery will not damaged by load, environment and rough usage cause various protection functions. The inside power components have low calorific value and the cooling fans are no need to long time run, so users will not be disturbed by the noise from fan.
1.Low frequency Pure sine wave for output.
2.The output voltage of inverter could not decreased with the capacity of battery lower or the capacity of load increase cause the inverter's power is sufficient
3.Low loss.
4.The inverter could be with instantaneous 3 times rated load at least. The air-condition, fridge and air pump could be used.
5.Digital and LED display is direct, simple and visual. User will not be disturbed by light or sound if press the mute and extinction button.
6.The type of battery could be chose;
7.The charging current could be chose;
8.The inverter could be started even no battery with normal AC.
9.Various protection functions: over charging, over discharging, over load, over temperature inside inverter, over temperature for life battery and output short and so on.
10.Various type of generator could be connected with input of inverter.
11.According to reality, the battery isolators could parallel or separate the vehicle battery and life battery.
12.Residential water and sweage level test switch for water pump function, (optional)
RV, Motor home, Ambulance, Bloodmobile, Rescue ambulance, Physical examination vehicle, Dental vehicle, Food&Drug testing vehicle, Military &Police vehicle, Media outside broadcasting vehicle, Helicopter, Yacht,etc.
Technical Parameters(Standard type) | ||
Model | CRV5000 | CRV8000 |
Rated Power(25°C) | 5000W/6250VA | 8000W/10000VA |
Rated Power(40℃) | 5000W/6250VA | 8000W/10000VA |
Peak Power | 15000W | 24000W |
Various combinations | ||
System voltage(DC) | 48V | 48V |
1 ON,2 ON | OA | 0A |
1 OFF.2OFF | 50A | 80A |
1 ON.2 OFF(factory default) | 30A | 50A |
1 OFFr2ON | 10A | 30A |
Inverter Mode | ||
Rated Voltage | 48VDC | |
Output Power | Nominal Value | |
Output Voltage | 220V/110V (110V Need to be customized) | |
Output Frequency | 50Hz/60Hz (60Hz Need to be customized) | |
Output Waveform | Pure sine wave | |
Efficiency | >85% | |
Peak Factor | 3:1 | |
Overload Capacity | 100%-120%>1min auto shut; 120%-150%>30s auto shut;above 150% 10s auto shut; | |
Overload Protection | Battery undervottage protection, battery undervoltage protection, battery undervoltage shutdown protection, output short circuit protection, inverter overtemperature protection, backup battery over temperature protection | |
Type of load | Resistive load, inductive load, capacitive load and half wave load | |
AC Mode | ||
Input Voltage Range | 160VAC~270VAC±5V(Beyond the range into the inverter mode) | |
Input Frequency Range | 38-65Hz(Beyond the range into the inverter mode) | |
Charging Voltage | 57.6V ±0.2V(48V System) | |
Charging Current(48V) | 0A,10A,30A,50A(factorydefault30A) | 0A,30A.50A.80A(factorydefault30A) |
Overload Protection | The over current protector is disconnected after overload | |
Other | ||
The inverter could be started in AC without battery. Generator:AII kinds of generator could be used(The power of generator is 1.5 times of inverter's.) | ||
Switching Time | AC to DC < 10ms; DCtoAC< 10ms | |
Protection Class | IP20 | |
Cooling Method | Forced air cooling | |
Water level monitoring | Optional | |
Temperature | Operating temperature: -40℃ ~50℃ | ;Storage temperature:-40℃ ~60℃ |
Working Humidity | 0%〜95% | |
Noise level | 4 40dB(1m) | |
No-load loss | 81W | 94.8W |
Display Information | working status,the voltage and frequency of input and output,the capacity of battery,the capacity of load.fault alarm | |
Product Size(mm) | 584(624)x306x190mm | 682(722)x410x199mm |
Package Size(cm) | 68.0x40.0x28.0cm | 72.0x40.0x28.0cm |
Net weight (kg) | 43.0 kg | 62.1kg |
Gross weight (kg) | 48.0kg | 66.01kg |
Backup Time | backup time(H)=battery capacity(Ah)÷discharge current(A) | |
Battery mode | External battery | |
Battery type | Lead-acid maintenance-free battery(including deep cycle battery)/GEL battery/Lithium polymer battery |
Note:“Output power” decreases as altitude increases,for example, 1500m the output power=rating power*0.94, 3500m the output power=rating power*0.82。
The date in the table above defaults to lead-acid maintenance-free batteries.
Specially available AC115V, AC120V, AC127V.